Mercury MP Pro 6k S Online UPS, 1.0PF, 6KVA/6KW, 1/1 Phase

Mercury MP Pro 6k S Online UPS, 1.0PF, 6KVA/6KW, 1/1 Phase
Key Features
Brand: Mercury
Capacity: 6kVA / 6kW
Power Factor: 1.0 PF
UPS Topology: True online double-conversion
Phase Configuration: Single-phase input/output (1/1)
Battery System: External 20 × 9Ah/12V sealed lead-acid (VRLA), 192VDC
Output Waveform: Pure sine wave
Input/Output Connections: Professional terminals (hardwired)
Communication Ports: RS232, USB, optional SNMP card
Efficiency: >90% AC-AC

1 Year Warranty

KSh 183,000.00

Guaranteed Safe Checkout

Features & Compatibility

Mercury MP Pro 6k S Online UPS, 1.0PF, 6KVA/6KW, 1/1 Phase
Key Features
Brand: Mercury
Capacity: 6kVA / 6kW
Power Factor: 1.0 PF
UPS Topology: True online double-conversion
Phase Configuration: Single-phase input/output (1/1)
Battery System: External 20 × 9Ah/12V sealed lead-acid (VRLA), 192VDC
Output Waveform: Pure sine wave
Input/Output Connections: Professional terminals (hardwired)
Communication Ports: RS232, USB, optional SNMP card
Efficiency: >90% AC-AC

1 Year Warranty

Mercury MP Pro 6k S Online UPS

The Mercury MP Pro 6k S represents an industrial-grade, single-phase double-conversion online UPS engineered for high-density enterprise environments and critical infrastructure protection. Featuring a true unity power factor, this high-capacity system delivers absolute power equalization to eliminate energy waste. The system provides continuous electrical purification and zero millisecond transfer speeds, shielding modular server racks, medical laboratories, and sensitive digital systems from all corporate grid anomalies. 
Core Engineering Capabilities
True Online Double-Conversion Architecture
The system completely decouples connected hardware from incoming utility grid anomalies. It continually changes raw input AC into clean DC voltage, then regenerates it back into a flawless AC output wave. This total isolation stops voltage sags, harmonic distortions, electrical line spikes, and frequency drifting from reaching downstream infrastructure. 
Unity Power Factor Optimization
The system operates at a true 1.0 power factor to provide complete electrical performance parity. This engineering design ensures the apparent power rating equals the active power capacity, delivering a full 6000 watts of usable energy. It maximizes space utilization and layout efficiency by eliminating traditional reactive power losses found in legacy systems.
Native Single-Phase Configuration
The electrical topology functions on a dedicated 1/1 phase electrical structure, requiring standard single-phase input and single-phase output connections. This native configuration simplifies electrical integration into standard building distribution panels. It avoids the complex load-balancing calculations and physical wiring costs associated with multi-phase installations
Advanced Digital Signal Processing Control
A high-speed centralized digital signal processor manages all internal power conversion phases, self-diagnostics, and automatic protection loops. This advanced digital intelligence optimizes overall operating efficiency and provides high-speed correction for sudden load fluctuations. It drastically lowers component stress and enhances long-term hardware reliability.
Intelligent Static and Maintenance Bypass
The unit integrates an automated static bypass alongside a dedicated mechanical maintenance bypass switch. The static bypass handles sudden circuit overloads or internal thermal spikes instantly without dropping the load. The mechanical maintenance switch allows technicians to service internal modules safely while keeping connected equipment powered by utility lines. 
Active Input Power Factor Correction
The unit incorporates automated correction circuitry to clean up power consumption at the source. It maintains a clean input power factor to eliminate electrical harmonic feedback into the building facility grid. This high-efficiency engineering lowers line current requirements and reduces building utility energy consumption overhead.
Smart Charging and Battery Health Protection
The advanced internal battery management system utilizes a multi-stage charging algorithm to condition connected energy storage banks. It prevents overcharging, deep discharge degradation, and thermal runaway within the battery architecture. This smart cycle management maximizes battery capacity retention and extends overall cell service life.
SMART Network Communication and SNMP Integration
The unit features communication interfaces alongside an advanced intelligent expansion slot. System administrators can install optional network management cards to enable remote tracking, email alarm triggers, and automated multi-server shutdown scripts. This allows centralized data teams to monitor system vitals across wide area networks. 
Automated High-Efficiency Eco Mode
The UPS incorporates an optional energy-saving mode to lower facility utility billing. When incoming grid power remains within strict pre-defined voltage thresholds, the system routes power efficiently through the internal bypass. If grid quality drifts outside safe parameters, the unit returns to full double-conversion mode instantly without a single millisecond of power interruption.
Cold Start and Isolated Emergency Initialization
The unit includes an integrated cold-start function that allows it to initialize power directly from its battery reserve. Technicians can turn on the UPS and access critical networking gear or save server data even when utility grid power is completely unavailable. This capability ensures immediate emergency power activation under any environmental condition.
Technical Specifications
  • Apparent Power Rating: 6000VA
  • Active Power Rating: 6000W
  • Power Factor Efficiency: 1.0 PF Unity
  • Phase Configuration: 1/1 Phase Single Input / Single Output
  • Transfer Time: Zero Milliseconds Continuous Output