HPE 96W Smart Storage Lithium‑ion Battery with 145mm Cable Kit

HPE 96W Smart Storage Lithium‑ion Battery with 145mm Cable Kit
Key Features
Brand: HPE
Provides 96W of backup power for HPE storage devices

Supports up to 20 devices simultaneously

Includes 145mm cable for easy connection and installation

Ensures data protection during power outages

1 Year Warranty

KSh 35,000.00

Guaranteed Safe Checkout

Features & Compatibility

HPE 96W Smart Storage Lithium‑ion Battery with 145mm Cable Kit
Key Features
Brand: HPE
Provides 96W of backup power for HPE storage devices

Supports up to 20 devices simultaneously

Includes 145mm cable for easy connection and installation

Ensures data protection during power outages

1 Year Warranty

HPE 96W Smart Storage Lithium-Ion Battery Kit Review: Cache Protection

The HPE 96W Smart Storage Lithium-Ion Battery with 145mm Cable Kit delivers critical energy backup and centralized flash memory data protection engineered for enterprise server environments. This original equipment manufacturer component acts as a hardware safety net for smart array storage controllers. It ensures that unwritten data cached in volatile memory is safely preserved during sudden datacenter power failures.
Executive Overview and Premium Design Philosophy
The HPE 96W Smart Storage Battery represents a core standard in data center protection and business continuity infrastructure. It transitions organizational networks from vulnerable, uncached storage configurations to a highly secure, resilient storage environment. Designed to support multiple storage controller cards across high-density ProLiant rack servers, blades, and syndication nodes, this premium factory component shields mission-critical database operations from sudden structural corruption risks. 
Engineered for Elite Professional Workflows
Enabling write-caching on hardware RAID controllers is an absolute requirement for modern high-performance databases, virtual desktop pools, and heavy file transactions. However, if a server loses power while data sits in the volatile controller cache, that information is lost. This lithium-ion battery kit resolves this vulnerability. If a sudden facility blackout occurs, the battery instantly provides sufficient backup power to flush cached data packets from volatile memory blocks into non-volatile, permanent flash storage arrays, protecting information assets.
Structural Integrity and Advanced Power Distribution Architecture
Constructed inside a compact, impact-resistant polymer shell, this unit features a dense lithium-ion internal cell array optimized to handle rapid discharge demands. Unlike low-grade aftermarket batteries that expand, leak, or degrade quickly under the high ambient heat of server rooms, this original equipment component contains specialized onboard thermal monitors. The kit includes a heavy-duty, 145mm low-resistance wiring harness with gold-plated contact pins that routes power directly to the server backplane or motherboard management bus
Key Technical Specifications
    • Product Type: Consolidated centralized backup energy storage battery kit
    • Battery Cell Chemistry: High-density Lithium-Ion (Li-ion) technology layout
    • Maximum Power Output: 96 Watts total power delivery threshold
    • Connecting Cable Length: 145 mm (14.5 cm) heavy-duty shielded wiring harness
    • Compatible Smart Array Controllers: HPE Smart Array P408i-a, P408i-p, P408e-p, P816i-a, and E208i-a Gen10 series
    • Compatible Server Platforms: HPE ProLiant DL360 Gen10, DL380 Gen10, ML350 Gen10, and XL Series
    • Integrated Smart Safety Logic: Built-in overcharge, undercurrent, and thermal monitoring micro-switches
    • Compatible Option Kit Numbers: 875241-B21, 879617-001, 727258-B21, and 815983-001 

Top Benefits of the HPE 96W Smart Storage Battery
Centralized Multi-Device Power Management
This consolidated battery module can power multiple smart array controllers simultaneously across a single server mainframe. This architectural layout eliminates the need to install separate, individual lithium battery packs onto every single add-in RAID controller card, which maximizes internal chassis space and simplifies hardware component oversight.
Safe Unlocking of Advanced Controller Write-Caching
HPE Smart Array controllers will automatically lock out high-speed write-caching performance features by default if a certified backup power source is missing. Installing this 96W battery kit immediately unlocks these advanced caching layers, which drastically speeds up server data writing metrics and database querying paths safely.
Intelligent Autonomous Battery Calibration Run
The battery module communicates natively with the HPE Integrated Lights-Out (iLO) system firmware to execute automated background diagnostics. It handles routine health monitoring checks, reports cell capacity metrics, and initiates periodic, autonomous charging calibration sweeps without needing manual intervention from IT field technicians.
True Toolless Drop-In Hardware Integration
The battery housing is engineered with explicit physical retention shapes built to match the designated backup power slots found inside ProLiant server frames. Field technicians can unbox the module, slide it neatly into place, click the security retention lock closed, and route the 145mm cable directly into the motherboard port without needing specialized hand tools.
Backup Energy Profile and Redundancy Allocation Matrix

Connected Storage Elements Caching Performance Status Data Preservation Capabilities Target Deployment Environment
No Battery Pack Present Restricted to Read-Only Caching No Protection for Transiting Data packets Standard Test Benches and Staging Configurations
96W Smart Kit Configured Full High-Speed Write Caching Non-Volatile Flash Memory Auto-Flushing Activated Mission Critical Databases and Multi-Tenant Hypervisors

Step-by-Step Server Hardware Installation Instructions
    1. Power Down System Safely: Shut down the server operating system completely, disconnect all active rear AC power cords, and remove the side access panel.
    2. Locate Battery Holding Bay: Identify the dedicated plastic battery retention tray located near the front intake fans or along the server sidewall.
    3. Seat the Battery Module: Align the 96W unit over the holding slot tracks and slide it down firmly until the plastic security clips lock into position.
    4. Connect the Routing Cable: Plug the 145mm wiring harness firmly into the designated smart storage battery port on the main server motherboard or midplane.
    5. Verify Initialization Health: Boot the system, open the HPE Smart Storage Administrator interface, and verify that the battery cell status reads as functional and fully charging.

Frequently Asked Questions
Can this 96W battery kit be utilized inside older ProLiant Gen9 servers?
Compatibility depends on the specific variant part number bundle you procure. While legacy ProLiant Generation 9 machines rely on a similar 96W lithium-ion battery blueprint, they typically require a significantly longer 300mm routing cable harness to clear their specific internal layout lanes. This particular kit features a short 145mm cable engineered primarily for the optimized layout of Generation 10 server chassis. 
What is the expected operational lifespan of this lithium-ion cell?
Under standard corporate data center environmental parameters, this enterprise lithium-ion battery module generally provides an active hardware lifecycle of approximately 3 to 5 years. Extreme temperature exposure or constant system power recycling can diminish cell storage volume over time, which will prompt an iLO dashboard warning when a replacement is required.
What occurs if the battery completely fails while the server is active?
If the internal charging monitoring circuit detects that the battery can no longer sustain a safe electrical charge threshold, it immediately triggers a critical system notification. To guarantee absolute data integrity, the smart array controller firmware will instantly disable high-speed write-caching performance features and default to standard read-through processing lines until a replacement kit is connected.