Mercury MDC3320S Online UPS, 20KVA/20KW, 3-Phase, 1.0 Power Factor
Key Features
Brand: Mercury
Model: Mercury MDC3320S
UPS Type: True Online Double-Conversion
Capacity: 20KVA / 20KW
Phase: 3-Phase Input / 3-Phase Output (3/3)
Power Factor: 1.0 (Unity)
Input Voltage: 400V AC ±10%
Frequency: 50/60 Hz auto-sensing
Input Terminal: Terminal block
Output Voltage: 400V AC ±1% (3-Phase)
Waveform: Pure Sine Wave
Voltage Regulation: ±1%
1 Year Warranty
Mercury MDC3320S Online UPS
The Mercury MDC3320S represents a premier industrial-grade 3-phase online UPS engineered for high-density enterprise environments, corporate data centers, and critical infrastructure installations. Featuring a true unity 1.0 power factor, this high-capacity system delivers complete power stabilization to eliminate energy waste across extensive equipment configurations. The true online double-conversion architecture provides continuous electrical purification and zero millisecond transfer speeds, shielding modular server networks, heavy manufacturing lines, and sensitive medical hardware from all grid anomalies.Â
True Online Double-Conversion Architecture
The system completely decouples connected hardware from incoming utility grid fluctuations. It continually converts raw input AC into clean DC voltage, then regenerates it back into a flawless pure sine wave AC output. This total isolation blocks voltage sags, harmonic distortions, line spikes, and frequency drifting from reaching downstream infrastructure.Â
Unity Power Factor Optimization
The system operates at a true 1.0 power factor to provide complete electrical performance parity. This engineering design ensures the apparent power rating equals the active power capacity, delivering a full 20000 watts of usable energy. It maximizes space utilization and layout efficiency by eliminating traditional reactive power losses found in lower-rated legacy systems.
Enterprise 3-Phase Input and Output Configuration
The electrical topology functions on a dedicated 3/3 phase infrastructure, requiring balanced three-phase input and three-phase output connections. This native layout ensures seamless integration into industrial power distribution networks and large server facilities. It maintains optimal phase balancing to prevent localized line overloads and minimize building wiring strain.
High-Voltage External Battery Architecture
The unit incorporates a specialized plus-minus 120VDC battery system configuration. This infrastructure utilizes two distinct sets of twenty 12V 9Ah sealed maintenance-free lead-acid batteries connected in series. Operating at a high DC bus voltage improves internal power conversion efficiency and reduces thermal losses during long-term blackouts.Â
True Zero Millisecond Transfer Time
The internal static bypass switch guarantees an instantaneous power handoff during primary utility grid failures. Because the internal inverter runs continuously, the transfer time to the 120VDC battery system measures exactly zero milliseconds. This absolute continuity prevents memory resets, dropped data packets, or hardware reboots in high-sensitivity processing units
Centralized Digital Signal Control
An advanced digital microprocessor handles all power conversion stages, real-time diagnostics, and automatic protection loops. This centralized digital intelligence optimizes operating efficiency and provides rapid response to sudden load variations. It minimizes component count to lower overall system failure rates over long-term operations.
Multi-Interface Monitoring and SMART Integration
The chassis incorporates standard USB, RS232, and RS485 communication ports alongside an intelligent expansion slot. Users can install optional SNMP network management cards to enable remote tracking, email alerts, and SCADA or BMS integration. This comprehensive connectivity allows IT administrators to monitor power parameters across wide area networks.
Smart Cooling and Thermal Management
Variable-speed cooling fans provide active thermal management during high-load operations. The system automatically adjusts internal fan speeds based on temperature sensors and power conversion demands. This intelligent regulation lowers noise levels below 55dB and reduces dust accumulation inside the chassis.Â
Automated System Eco-Mode Functionality
The unit features an optional high-efficiency mode to reduce building energy overhead. When grid power quality stays within strict pre-defined thresholds, the system routes power efficiently through the static bypass. If grid metrics drift, the UPS instantly switches back to full double-conversion mode without interrupting operations.
Comprehensive Industrial Circuit Protection
Internal sensors monitor structural heat, current spikes, and sudden output load variations continuously. The unit automatically safeguards internal components against lightning strikes, overloads, and output short circuits. It triggers visual alerts on the interface panel to prompt operator inspection without dropping the primary load
Technical Specifications
- Apparent Power Rating: 20KVA
- Active Power Rating: 20KW
- Power Factor Efficiency: 1.0 PF Unity
- Phase Configuration: 3-Phase Input / 3-Phase Output (3/3)
- System Battery Voltage: ±120VDC Architecture
- Transfer Time: Zero Milliseconds Continuous Output